Hemodialysis

Effect of needle orientation during arteriovenous access puncture on needed compression time after hemodialysis: A randomized controlled trial

Hemodial IntPublished Randomised controlled trial

Authors' conclusion

Bevel-up and bevel-down needle orientation during arteriovenous fistula puncture are equivalent techniques in terms of achieving hemostasis on needle removal, and puncture-associated pain.

Study context

Population
HD patients with an AVF
Participants
42 patients
Comparison
Bevel-down vs bevel-up needle insertion for AVF puncture
Primary endpoint
Minimum compression time required for hemostasis after needle removal
Methodological detailsprospective, cross-over, blinded, single-center, routine care study
  • Prospective
  • Cross-over
  • Blinded
  • Single-center
  • Routine care study

Primary result

As reported in the abstract

Minimum post-dialysis compression time

P = 0.72

Further findings

Puncture-associated pain

No difference in puncture-associated pain between the two insertion techniques

Prepump and venous pressures, desired blood flow rate

No difference in prepump or venous pressures or ability to achieve the desired blood flow rate

Original publication

Effect of needle orientation during arteriovenous access puncture on needed compression time after hemodialysis: A randomized controlled trial. Hemodial Int. Published 6 July 2023. doi:10.1111/hdi.13105