Hemodialysis

Effect of Hemodiafiltration or Hemodialysis on Mortality in Kidney Failure

N Engl J MedPublished Randomised controlled trial

Primary result · Death from any causeResult — go to the resultHazard ratio 0.77 95% CI 0.65–0.93

Authors' conclusion

In patients with kidney failure resulting in kidney-replacement therapy, the use of high-dose hemodiafiltration resulted in a lower risk of death from any cause than conventional high-flux hemodialysis.

Study context

Population
Patients with kidney failure on high-flux HD for at least 3 months, candidates for a convection volume of at least 23 liters per session and able to complete patient-reported outcome assessmentsmedian follow-up 30 months
Participants
1,360 patients
Comparison
High-dose HDF vs continuation of conventional high-flux HD
  • Hemodiafiltrationn = 683
  • Hemodialysisn = 677reference
Primary endpoint
Death from any cause
Methodological detailspragmatic, multinational
  • Pragmatic
  • Multinational

Primary result

Death from any cause · median follow-up 30 months (IQR 27 to 38)

Hazard ratio

0.77

95% CI 0.65–0.93

Events by treatment group

Hemodiafiltrationvs Hemodialysis
HR 0.77 (95% CI 0.65–0.93)

As reported in the abstract

Secondary outcomes

Convection volume during the trial, Hemodiafiltration
25.3 · mean · liters per session

Original publication

Effect of Hemodiafiltration or Hemodialysis on Mortality in Kidney Failure. N Engl J Med. Published 16 June 2023. doi:10.1056/nejmoa2304820

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.