Effect of Hemodiafiltration or Hemodialysis on Mortality in Kidney Failure
Primary result · Death from any causeResult — go to the resultHazard ratio 0.77 95% CI 0.65–0.93Authors' conclusion
In patients with kidney failure resulting in kidney-replacement therapy, the use of high-dose hemodiafiltration resulted in a lower risk of death from any cause than conventional high-flux hemodialysis.
Study context
- Population
- Patients with kidney failure on high-flux HD for at least 3 months, candidates for a convection volume of at least 23 liters per session and able to complete patient-reported outcome assessmentsmedian follow-up 30 months
- Participants
- 1,360 patients
- Comparison
- High-dose HDF vs continuation of conventional high-flux HD
- Hemodiafiltrationn = 683
- Hemodialysisn = 677reference
- Primary endpoint
- Death from any cause
Methodological detailspragmatic, multinational
- Pragmatic
- Multinational
Primary result
Death from any cause · median follow-up 30 months (IQR 27 to 38)
Hemodiafiltrationvs Hemodialysis
HR 0.77 (95% CI 0.65–0.93)
As reported in the abstract
Secondary outcomes
- Convection volume during the trial, Hemodiafiltration
- 25.3 · mean · liters per session
Original publication
Effect of Hemodiafiltration or Hemodialysis on Mortality in Kidney Failure. N Engl J Med. Published 16 June 2023. doi:10. 1056/ nejmoa2304820