Electrolytes, acid–base & stones
Effect of a single small volume fluid bolus with balanced or un-balanced fluids on chloride and acid–base status: a prospective randomized pilot study (the FLURES-trial)
Authors' conclusion
Even a single, small bolus of saline, administered to critically ill patients, causes a significant increase in chloride concentration and a decrease in apparent strong ion difference and base excess, and an increase in the number of patients developing hyperchloremia. No difference in effect on urinary output, blood pressure or vasopressor need was observed between the two groups.
Study context
- Population
- Adult patients (≥ 18 years) admitted to the ICU receiving a fluid bolus
- Comparison
- 1 L saline vs 1 L Plasmalyte® fluid bolus
- Primary endpoint
- Short-term effects on acid base, electrolyte status and urine output
- Follow-up
- Three hours after termination of the fluid bolus
Methodological detailsprospective, pilot
- Prospective
- Pilot
Primary result
As reported in the abstract
Serum chloride; significant increase with saline; measure not named in the abstract
1.60
95% CI 1.10–2.10P < 0.001
Apparent strong ion difference; short-term decrease with saline; measure not named in the abstract
- 1.85
95% CI - 2.71 to - 0.99P < 0.001
Base excess; short-term decrease with saline; measure not named in the abstract
- 0.90
95% CI - 1.31 to - 0.50P < 0.001
Further findings
| Outcome | Estimate | P value |
|---|---|---|
| Patients developing hyperchloremia17% increase in the saline group | 0.17 (95% CI 0.05–0.29) | P = 0.005 |
Urinary output, BP, vasopressor need
- No significant difference in urinary output, blood pressure or vasopressor need in either group
Original publication