Electrolytes, acid–base & stones
Early postoperative weight-based fluid overload is associated with worse outcomes after neonatal cardiac surgery
Authors' conclusion
POD2 weight-based fluid balance > 10% occurs frequently after neonatal cardiac surgery and is associated with longer cardiorespiratory support and postoperative hospital LOS. However, POD2 FB-IO was not associated with clinical outcomes. Mitigating early postoperative fluid accumulation may improve outcomes but requires safely weighing neonates in the early postoperative period.
Study context
- Population
- Neonates after cardiac surgery (cardiopulmonary bypass (CPB) and non-CPB) weighed on POD2, 22 hospitals of the NEonatal and Pediatric Heart and Renal Outcomes Network (NEPHRON) registry, September 2015 to January 2018CPB 658, non-CPB 339
- Participants
- 997 neonates
- Exposure
- POD2 FB-W >10% vs ≤10%
- FB-W >10%n = 444
- Outcome
- Outcomes after neonatal cardiac surgery:
- Hospital mortality
- Utilization outcomes
Methodological detailsmulticentre (22 hospitals), NEPHRON registry
- Multicentre (22 hospitals)
- NEPHRON registry
Main finding
As reported in the abstract
Multiplicative rate
- Duration of mechanical ventilation
- 1.19 (95% CI 1.04–1.36)
- Respiratory support
- 1.28 (95% CI 1.07–1.54)
- Inotropic support
- 1.38 (95% CI 1.10–1.73)
- Postoperative hospital LOS
- 1.15 (95% CI 1.03–1.27)
- Hospital mortality, all patients
- 2.8% (n = 28)
Key notes
- Patients with POD2 FB-W >10% had higher acuity of illness and worse outcomes
Observational data: associations, not effects.
Further findings
POD2 FB-W as a continuous variable
| OR (95% CI) | ||
|---|---|---|
| POD2 FB-W (continuous)Prolonged mechanical ventilation | 1.04 (1.02–1.06) | |
| 0.512Odds ratio (log scale) |
POD2 FB-W as a continuous variable · POD2 FB-W (continuous)
| Outcome | Estimate |
|---|---|
| Respiratory support | 1.03 (95% CI 1.01–1.05) |
| Inotropic support | 1.03 (95% CI 1.00–1.05) |
| Postoperative hospital LOS | 1.02 (95% CI 1.00–1.04) |
POD2 intake-output based fluid balance (FB-IO)
- POD2 FB-IO not associated with any outcome
Original publication