Early detection of arteriovenous fistula problems among pediatric patients on hemodialysis
Authors' conclusion
AVF dysfunction is frequent in pediatric HD patients. DUS is superior to physical examination for early detection. Intradialytic VP and TMP are useful early markers of impending dysfunction. hs-CRP showed a potential value in identifying stenosis, while other inflammatory markers show limited utility. A combined surveillance approach using clinical assessment, DUS, and hemodynamic monitoring is recommended to improve AVF outcomes.
Study context
- Population
- Pediatric patients (< 18 years) with chronic kidney disease (CKD) stage 5 on maintenance hemodialysis (HD) via functioning arteriovenous fistula (AVF)followed 12 months
- Participants
- 59 patients
- Exposure
- Physical examination vs duplex ultrasonography (DUS) for detection of AVF dysfunction
- Outcome
- AVF complications
- Follow-up
- 12 months
Main finding
As reported in the abstract
AVF complications
55.9%
Thrombosis
28.8%
Aneurysm
23.7%
Stenosis
10.2%
Observational data: associations, not effects.
Further findings
| Outcome | Physical examination |
|---|---|
| Diagnostic accuracy of physical examination vs DUSCompared with DUS | |
| Sensitivity | 66.7% |
| Specificity | 100% |
Intradialytic venous pressure (VP) and transmembrane pressure (TMP)
- Elevated VP and TMP were early indicators of dysfunction, significantly increased prior to structural changes on DUS
- P < 0.001
Inflammatory biomarkers · complication onset
- hs-CRP and IL-10 increased significantly at complication onset and were specifically elevated in stenosis
- TNF-α showed only a non-significant trend
DUS findings by complication
- Aneurysm linked to higher flow volume and diameter; thrombosis linked to reduced diameter and flow
Original publication