Dual‐Energy X‐Ray Absorptiometry‐Derived Advanced Hip Analysis and the Trabecular Bone Score Are Associated With the Diagnosis of Fracture Following Kidney and Simultaneous Pancreas‐Kidney Transplantation
Authors' conclusion
BMD, the TBS, and AHA parameters are associated with incident fracture in kidney-only and SPK transplant recipients. Pre-transplant smoking, lower 25-hydroxyvitamin D and BMD are potentially modifiable factors that could reduce post-transplant fracture risk.
Study context
- Population
- Kidney-only or simultaneous pancreas-kidney (SPK) transplant recipients undergoing immediate post-transplant dual-energy x-ray absorptiometry289 (83%) kidney-only
- Participants
- 357 participants
- Outcome
- Incident post-transplant fracture
Methodological detailsKaplan-Meier and Cox proportional hazard models, multivariable adjustment, Patients received treatment to reduce post-transplant bone mineral density (BMD) loss, using an established risk algorithm
- Kaplan-Meier and Cox proportional hazard models
- Multivariable adjustment
- Patients received treatment to reduce post-transplant BMD loss, using an established risk algorithm
Main finding
As reported in the abstract
Incident fracture · median of 4.4 years (IQR: 2.5-5.5)
- Incident fractures
- 83
- Fracture associated with type 1 diabetes mellitus
- p < 0.001
- Fracture associated with former smoking
- p = 0.006
- Fracture associated with lower 25-hydroxyvitamin D
- p = 0.003
- Fracture associated with BMD at total proximal femur and neck of femur
- p < 0.001
- Fracture associated with spine BMD
- p = 0.008
- Fracture associated with lower cortical thickness (CTh) at the calcar
- p = 0.005
- Fracture associated with lower CTh at the shaft
- p = 0.023
- Fracture associated with higher buckling ratio (BR)
- p = 0.016
- Fracture associated with lower trabecular bone score (TBS)
- p = 0.047
Key notes
- After multivariable adjustment, type 1 diabetes mellitus, 25-hydroxyvitamin D, smoking and femoral neck BMD remained significant
Further findings
Fracture prediction model
- Inclusion of the BR in the BMD-based risk algorithm improved the model fit
Original publication
Dual‐Energy X‐Ray Absorptiometry‐Derived Advanced Hip Analysis and the Trabecular Bone Score Are Associated With the Diagnosis of Fracture Following Kidney and Simultaneous Pancreas‐Kidney Transplantation. Clin Transplant. Published 11 May 2025. doi:10. 1111/ ctr. 70177