Dried blood spot versus intravenous iohexol and 99mTc-DTPA for GFR measurement and model-based analysis of renal drug clearance

Nephrol Dial TransplantPublished Method comparison study

Authors' conclusion

Compared to intravenous sampling of iohexol or 99mTc-DTPA, DBS sampling of iohexol yielded similar improvements to model fit when incorporated as a covariate on gentamicin clearance in a popPK model.

Study context

Population
Older patients aged ≥65 years with poor appetite (Simplified Nutritional Appetite Questionnaire (SNAQ) score ≤14); gentamicin 5 mg/kg IV as model drug51% male, aged 67–96
Participants
51 patients
Comparison
Dried blood spot (DBS) iohexol vs intravenous 99mTc-DTPA, each relative to intravenous iohexol, and as covariates on gentamicin clearance
Outcome
Model fit of gentamicin popPK model with mGFR as covariate on clearance
Methodological detailspopulation pharmacokinetic modeling, traditional performance statistics
  • Population pharmacokinetic modeling
  • Traditional performance statistics

Main finding

As reported in the abstract

Model fit of gentamicin popPK model with mGFR as covariate on clearance

All three measured glomerular filtration rate (mGFR) methods improved model fit (-ΔOFV)

115.6-137.6

Further findings

OutcomeDBS iohexolIntravenous 99mTc-DTPA
Performance relative to intravenous iohexol
Bias (median difference)2 [0-3] mL/min (95% CI)4 [3-5] mL/min
P1598% [94.1%-100%]78.4% [66.7%-88.2%]

Performance relative to intravenous iohexol

DBS iohexol performed better than intravenous 99mTc-DTPA

Original publication

Dried blood spot versus intravenous iohexol and 99mTc-DTPA for GFR measurement and model-based analysis of renal drug clearance. Nephrol Dial Transplant. Published 11 June 2026. doi:10.1093/ndt/gfag130