Donor‐Recipient Size Mismatch by Body Surface Area and Risk of Graft Failure in Kidney Transplantation
Authors' conclusion
BSA mismatch, specifically under sizing, was independently associated with worse graft and patient outcomes. The BSA ratio adds prognostic value beyond standard variables and may improve allocation by accounting for nephron adequacy.
Study context
- Population
- Adult deceased donor kidney-only transplants in the US, 2010–201538,545 transplants
- Exposure
- Undersized or oversized vs matched grafts by donor-to-recipient body surface area (BSA) ratio
- Outcome
- Death-censored graft failure (DCGF), all-cause graft failure (ACGF), patient mortality and delayed graft function (DGF)
Methodological detailsnational registry data, complete 10-year follow-up, multivariable Cox and logistic regression models
- National registry data
- Complete 10-year follow-up
- Multivariable Cox and logistic regression models
Main finding
As reported in the abstract
Graft and patient outcomes
Undersized vs MatchedEstimate (95% CI)P value
DCGF
HR 1.11(1.07–1.15)
P < 0.01ACGF
HR 1.10(1.06–1.14)
P < 0.01Mortality
HR 1.07(1.03–1.12)
P < 0.01DGF
OR 1.09(1.03–1.16)
P < 0.01Key notes
- Oversized grafts showed no significant differences
- Adjusted for donor, recipient, and transplant factors
Observational data: associations, not effects.
Further findings
Stricter undersized thresholds
- HR at BSA ratio <0.85
- 1.13
- HR at BSA ratio <0.8
- 1.17
- Risk increased stepwise, indicating a dose-dependent relationship
Original publication
Donor‐Recipient Size Mismatch by Body Surface Area and Risk of Graft Failure in Kidney Transplantation. Clin Transplant. Published 16 June 2026. doi:10. 1111/ ctr. 70596
Composed by AI from the published abstract and checked against it. How Briefs are made →