Hemodialysis

Direct Hemoperfusion with Polymethylmethacrylate for Hemodialysis Patients with Dialysis-Related Amyloidosis

Blood PurifPublished Prospective cohort study

Authors' conclusion

Direct hemoperfusion with PMMA is an effective method for removing β2-m in hemodialysis patients with DRA. Beneficial effects were also observed for the removal of α1-m and MMP-3. Further research is required to evaluate the long-term efficacy of this approach in managing DRA. </p>.

Study context

Population
HD patients diagnosed with dialysis-related amyloidosis (DRA)
Participants
10 patients
Exposure
Dialysis filter plus polymethylmethacrylate (PMMA) cartridges vs dialysis filter alone
Outcome
Removal rates and clearances of β2-microglobulin (β2-m)

Main finding

As reported in the abstract

β2-m removal · 240 min
  • PMMA cartridge increased β2-m removal rates vs dialysis filter alone for treatment duration of 240 min
  • β2-m clearance improved with the addition of PMMA cartridges, depending on the cartridge size

Observational data: associations, not effects.

Further findings

α1-m and MMP-3 removal

Removal rates of α1-m and MMP-3 higher with PMMA cartridges than with dialysis filter alone
α1-m and MMP-3 clearance improved with the addition of PMMA cartridges, depending on the cartridge size

IL-6 and TNF-α removal · 30 min and 240 min

Removal rates of IL-6 and TNF-α higher with PMMA cartridges than with dialysis filter alone at 30 min, but not at 240 min

Original publication

Direct Hemoperfusion with Polymethylmethacrylate for Hemodialysis Patients with Dialysis-Related Amyloidosis. Blood Purif. Published 5 August 2025. doi:10.1159/000546771

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.