Pediatric nephrology

Developing a trigger tool to monitor adverse events during haemodialysis in children: a pilot project

Pediatr NephrolPublished Quality improvement study

Authors' conclusion

This pilot study demonstrates potential benefits of a bedside tool to monitor adverse events during haemodialysis in children. Thus, following interventions informed by the pHTT, the harm rate per session was significantly reduced. Under standard patient safety systems, the vast majority of triggers identified by the pHTT would remain unreported and perhaps lead to missed opportunities to improve patient safety. We propose the use of a paediatric HTT as part of standard care by centres providing HD to children in the future.

Study context

Population
Children receiving intermittent in-centre haemodialysis (HD), age range 28–205 months182 dialysis sessions
Participants
13 vs 15
Exposure
Second cycle vs first cycle
  • Second cyclen = 13
  • First cyclen = 15reference
Outcome
Harm rate per HD session
Methodological detailssingle-centre, pilot, two 8-week cycles, prospective data collection, paediatric haemodialysis trigger tool (pHTT) of 54 triggers across six domains, adapted from an adult haemodialysis trigger tool (HTT); completed by HD nurses at the end of each session; harm level assessed by two authors
  • Single-centre
  • Pilot
  • Two 8-week cycles
  • Prospective data collection
  • pHTT of 54 triggers across six domains, adapted from an adult HTT; completed by HD nurses at the end of each session; harm level assessed by two authors

Main finding

As reported in the abstract

Harm rate per session

First cycle

1.03

94 of 15

Second cycle

0.32

29 of 13

P < 0.001

Observational data: associations, not effects.

Further findings

Events

OutcomeFirst cycleSecond cycle
Triggers139102
Triggers — Total triggers over 182 sessions
241
Distribution of triggers by harm category · significant difference
P < 0.001
Proportion of triggers across pHTT domains · significant difference
P = 0.004

Safety

No triggers were evaluated as causing permanent harm

Original publication