Peritoneal & home dialysis

Determining the residual volume in peritoneal dialysis using low molecular weight markers

Perit Dial IntPublished Retrospective clinical study

Authors' conclusion

Mass-transfer of low molecular weight marker molecules is associated with residual volume overestimation. However, by applying correction factors, creatinine and urea dilution can still provide reasonable estimates, particularly when the purpose is to exclude the presence of a very large residual volume.

Study context

Population
PD patients56 residual volume estimations
Participants
20 patients
Exposure
Creatinine- and urea-based vs albumin-based residual volumes and three-pore model estimations
Outcome
Residual volume estimation accuracy of creatinine and urea as dilution markers
Methodological detailsthree-pore model estimations, linear regression conversion factors
  • Three-pore model estimations
  • Linear regression conversion factors

Main finding

As reported in the abstract

Overestimation of residual volume by creatinine-based calculations

Creatinine overestimation, 1.5% dwells

115 mL

IQR 89–149

Creatinine overestimation, 4.25% glucose dwells

252 mL

IQR 179–313

Observational data: associations, not effects.

Further findings

Ultrafiltration and creatinine mass during fill, hypertonic dwells

Ultrafiltration
52 mL (IQR 38-66)
Intraperitoneal creatinine mass increase during fill (leading cause of overestimation)
67%

Original publication