Determinants of Urine Output Using Advanced Hemodynamic Monitoring in Critically Ill Patients Undergoing Continuous Renal Replacement Therapy
Authors' conclusion
In ICU patients treated with CRRT, those without anuria showed a rapid loss of diuresis after CRRT initiation. Hemodynamic indicators of renal perfusion and effective volemia were the principal determinants of UO during follow-up, in relation with the hemodynamic impact of UFNET setting.
Study context
- Population
- Adult intensive care unit (ICU) patients with severe AKI treated with CRRT for less than 24 h, monitored with a calibrated continuous cardiac output monitoring deviceage 68 [58–76] years
- Participants
- 42 patients
- Comparison
- Non-anuric vs anuric at inclusion
- Non-anuricn = 32
- Primary endpoint
- Hemodynamic parameters and CRRT settings associated with the longitudinal course of UO during CRRT
- Follow-up
- Over 7 days
Methodological detailsancillary analysis, single-center, 4-hourly measurements over 7 days, multivariate analyses
- Ancillary analysis
- Single-center
- 4-hourly measurements over 7 days
- Multivariate analyses
Primary result
As reported in the abstract
Determinants of UO (multivariate analyses) · during follow-up
- Lower UO significantly associated with lower SVI, lower mean arterial pressure (MAP) and preload-independence
- Higher UFNET significantly associated with lower UO
Further findings
| Outcome | Non-anuric |
|---|---|
| Progression to anuria in non-anuric patients · during follow-up | 78% |
| Time to anuria, median [IQR] | 19 [10-50] hours |
- Progression to anuria in non-anuric patients: 25/32
Progression to anuria in non-anuric patients · during follow-up
- UO decreased significantly in non-anuric patients
MAP and UFNET between study groups · during follow-up
- MAP and UFNET did not significantly differ between study groups
- SVI and preload-dependence significantly associated with the interaction of study group and time since inclusion
UFNET and hemodynamics · during follow-up
- Higher UFNET flow rates significantly associated with higher systemic vascular resistances and lower cardiac output
Original publication
Determinants of Urine Output Using Advanced Hemodynamic Monitoring in Critically Ill Patients Undergoing Continuous Renal Replacement Therapy. Blood Purif. Published 16 December 2023. doi:10. 1159/ 000535544
Composed by AI from the published abstract and checked against it. How Briefs are made →