Hemodialysis

Constant Fluid Removal Associates With Greater Risk of Elevated High‐Sensitivity Troponin I Than Downward Sloping Profile Among Maintenance Dialysis Patients With High Ultrafiltration

Hemodial IntPublished Crossover study

Authors' conclusion

In maintenance dialysis patients with high ultrafiltration, constant fluid removal is associated with a rise in hs Tn I, and a downward sloping profile may be safer than constant fluid removal.

Study context

Population
Patients on maintenance HD thrice weekly with UF rates > 13 mL/kg/h and without known cardiac disease504 dialysis sessions
Participants
42 patients
Comparison
Constant UF vs downward sloping profiled UF
Outcome
MAP trends and dialysis-associated hs-TnI change (pre-to-post HD)
Methodological detailswithin-patient comparison of 6 constant and 6 downward sloping profiled UF sessions
  • Within-patient comparison of 6 constant and 6 downward sloping profiled UF sessions

Main finding

As reported in the abstract

Δ post-pre-HD hs TnI
Constant UF type associated with 27 times greater odds of a 10% rise in hs TnI (multivariate logistic regression)
27

Further findings

OutcomeP value
MAP and intradialytic hypotensionTrend toward higher post-HD pressures with profiled UFP = 0.08

MAP and intradialytic hypotension

MAP and intradialytic hypotension did not differ significantly between constant and profiled sessions

Original publication

Constant Fluid Removal Associates With Greater Risk of Elevated High‐Sensitivity Troponin I Than Downward Sloping Profile Among Maintenance Dialysis Patients With High Ultrafiltration. Hemodial Int. Published 9 November 2025. doi:10.1111/hdi.70030

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.