Electrolytes, acid–base & stones

Comparison of two different bicarbonate replacement fluids during continuous veno-venous hemofiltration (CVVH) with RCA: a prospective, randomized, controlled trial

Intensive Care MedPublished Randomised controlled trial

Authors' conclusion

LBF showed significantly lower rates of pH and HCO3- excursions compared to HBF and no significant differences to the pH normalization in acidotic patients were observed.

Study context

Population
Patients on CVVH with regional citrate anticoagulation
Participants
88 patients
Comparison
High vs low bicarbonate replacement fluid during CVVH with regional citrate anticoagulation
Primary endpoint
At least one pH/HCO3- excursion outside standard values
Follow-up
96 h (two 48-h phases)
Methodological detailsprospective, open-label, cross-over, single-center
  • Prospective
  • Open-label
  • Cross-over
  • Single-center

Primary result

As reported in the abstract

≥1 pH and HCO3- excursion (levels outside standard values)

pH, first phase

pH, second phase

HCO3-, first phase

HCO3-, second phase

Adjusted OR for ≥1 pH excursion
1.78 (95% CI 1.12-2.82; p = 0.015)
Adjusted OR for ≥1 HCO3- excursion
3.60 (95% CI 2.16-5.99; p < 0.001)

Further findings

Time to normalization (pH in acidotic patients; HCO3- in low HCO3-), first phase · HBF vs LBF

OutcomeP value
pHP = 0.102
HCO3-P = 0.468
Did not differ significantly between HBF and LBF

Original publication