Comparison of Resistive Index and Volume Flow in Ultrasound of Arteriovenous Fistula for Dialysis Access
Authors' conclusion
The addition of resistive index values can support confidence in the technically difficult volume flow measures, especially for sonographers with non-specialized vascular skills.
Study context
- Population
- Patients presenting with an upper limb AVF to two vascular US practices in Australia, January 2017 to October 20211,988 US examinations
- Exposure
- Resistive index cutoffs for predicting volume flow ≥ 500 mL/min
- Outcome
- PPV of resistive index ≤ 0.65 and ≤ 0.75 for a volume flow of ≥ 500 mL/min
Methodological detailstwo vascular ultrasound practices in Australia, 1988 US examinations by 9 sonographers; eight AVF types noted
- Two vascular ultrasound practices in Australia
- 1988 US examinations by 9 sonographers; eight AVF types noted
Main finding
As reported in the abstract
PPV of resistive index for volume flow ≥ 500 mL/min
| Group | PPV, resistive index ≤ 0.65 | PPV, resistive index ≤ 0.75 |
|---|---|---|
| Surveillance | 96.8% | 95.4% |
| Problematic AV fistula | 92.5% | 83.8% |
PPV, resistive index ≤ 0.65
Surveillance96.8%
Problematic AV fistula92.5%
PPV, resistive index ≤ 0.75
Surveillance95.4%
Problematic AV fistula83.8%
Observational data: associations, not effects.
Further findings
- Significant differences in median resistive index and volume flow between AVF type and indication for study
- AVF types analysed: radio-cephalic (1267), brachiocephalic (491), brachio-basilic (193) examinations
Original publication
Comparison of Resistive Index and Volume Flow in Ultrasound of Arteriovenous Fistula for Dialysis Access. Hemodial Int. Published 30 June 2026. doi:10. 1111/ hdi. 70100
Composed by AI from the published abstract and checked against it. How Briefs are made →