Comparison of radioactive and non-radioactive iothalamate and hippuran to assess kidney function
Authors' conclusion
The cold method provides equivalent mGFR results compared with the warm method. The ERPF determined using the cold method is unaffected by radiochemical impurities that significantly affect the warm method.
Study context
- Population
- Participants with measured glomerular filtration rate (mGFR) and effective renal plasma flow (ERPF) determination
- Participants
- 220 participants
- Comparison
- Cold method vs warm method
- Outcome
- Agreement of mGFR between warm and cold methods; accuracy criteria ≥80% within ±30% (P30) and ≥50% within ±10% (P10)
Methodological detailssame serum, urine and infusion solution samples, Passing-Bablok regression, Bland-Altman analysis
- Same serum, urine and infusion solution samples
- Passing-Bablok regression
- Bland-Altman analysis
Main finding
mGFR agreement
- P30
- 100%
- P10
- 76%
- SD of bias (cold method precision)
- 8.04 ml/min
- Intratest CV%
- 3.01 ± 3.15%
Key notes
- No clinically relevant bias
Further findings
ERPF agreement, warm vs cold method
- ERPF mean difference
- 19.2%
- Large constant and proportional bias
- Radiochemical impurities in the 131I-hippuran formulation, influencing the warm method, caused the discrepancy
Parts of this Brief are withheld: the automatic checks could not confirm them against the abstract.
Original publication
Comparison of radioactive and non-radioactive iothalamate and hippuran to assess kidney function. Clin Kidney J. Published 23 September 2025. doi:10. 1093/ ckj/ sfaf293