Hemodialysis

Comparison of High-Flux, Super High-Flux, Medium Cut-Off Hemodialysis and Online Hemodiafiltration on the Removal of Uremic Toxins

Blood PurifPublished Prospective study

Authors' conclusion

This study confirms that albumin loss and removal of MM are similar using conventional Elisio 21H™ OL-HDF, MCO-HD, and SHF type V dialyzers. Although Renak PS-2.0W™ OL-HDF provides high performance for MM depuration, this protein-permeable dialyzer should not be used in OL-HDF because of excessive albumin loss.

Study context

Population
Hemodialysis (HD) patients9 sessions each
Participants
8 patients
Exposure
HD with 7 different dialyzers vs online hemodiafiltration (OL-HDF) with 2 dialyzers
  • Theranova 500™ HDn = 8
  • Elisio 21H™ HDn = 8reference
  • Renak PS-2.0W™ HDn = 8
  • Filtryzer BK-2.1F™ HDn = 8
  • Vie 21X™ HDn = 8
  • TS-2.1UL™ HDn = 8
  • FDY 210-GW™ HDn = 8
  • Elisio 21H™ OL-HDFn = 8
  • Renak PS-2.0W™ OL-HDFn = 8
Outcome
Small solute and middle molecule RR and mass removal
Methodological detailseach patient underwent all 9 dialysis sessions
  • Each patient underwent all 9 dialysis sessions

Main finding

As reported in the abstract

Beta2-microglobulin mass removal

P < 0.05

Observational data: associations, not effects.

Further findings

Kappa FLC mass removal — Renak PS-2.0W™ OL-HDF vs Elisio 21H™ HD · higher with Renak PS-2.0W™ OL-HDF

P < 0.01

OutcomeP value
Kappa FLC mass removalRenak PS-2.0W™ OL-HDF vs Renak PS-2.0W™ HD · higher with Renak PS-2.0W™ OL-HDFP < 0.05

Urea

Urea mass removal and RR similar between all dialysis strategies

Beta2-microglobulin RR

Lowest beta2-microglobulin RR with Filtryzer BK-2.1F™ HD
P < 0.05

Kappa and lambda FLC RR

Higher RR with Theranova 500™ HD, Vie 21X™ HD, FDY 210-GW™ HD, Elisio 21H™ OL-HDF and Renak PS-2.0W™ OL-HDF vs Elisio 21H™ HD and Filtryzer BK-2.1F™ HD
P < 0.05

Safety

Albumin loss — Renak PS-2.0W™ OL-HDF vs all other strategies · significantly higher with Renak PS-2.0W™ OL-HDF · range across strategies

P < 0.05

Original publication

Comparison of High-Flux, Super High-Flux, Medium Cut-Off Hemodialysis and Online Hemodiafiltration on the Removal of Uremic Toxins. Blood Purif. Published 10 October 2022. doi:10.1159/000526891

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.