Comparison of clean catch and bag urine using LC–MS/MS proteomics in infants
Authors' conclusion
Urinary proteomics shows a high correlation with minor variation in low-abundant proteins between the two urine collection methods. The biological characteristics overrule this variation.
Study context
- Population
- Infants (9 boys, 7 girls; mean age 4.3 ± 2.9 months): 5 post-pyelonephritis, 10 non-kidney disease, 1 chronic kidney disease (CKD)32 urine samples
- Comparison
- Clean catch vs bag urine
- Outcome
- Urinary proteome by collection method
Methodological detailsLC-MS/MS in data-independent acquisition mode, paired samples within 24 h
- LC-MS/MS in data-independent acquisition mode
- Paired samples within 24 h
Main finding
As reported in the abstract
Urinary proteome by collection method
Slightly, but insignificantly higher in clean catch
- Total urinary proteins detected
- 1454
- Top-abundant proteins accounting for 50% of total abundance
- 18
- Median intensity higher in clean catch
- 1.2 ×
- Differential detection of proteins between collection methods
- 29%
- Differential detection in the 96 top-abundant proteins
- 3%
- Pearson's correlation coefficient (high intraindividual correlation)
- 0.81 ± 0.11
Key notes
- Principal component analysis and heat map clustered by diagnoses and patients rather than collection method
- Albumin and α-1-microglobulin detected the most
More notes
- Slightly, but insignificantly higher in clean catch
Original publication
Comparison of clean catch and bag urine using LC–MS/MS proteomics in infants. Pediatr Nephrol. Published 31 July 2023. doi:10. 1007/ s00467-023-06098-3
Composed by AI from the published abstract and checked against it. How Briefs are made →