Pediatric nephrology

Comparison of axial and coronal axis MRI kidney volume measurement in pediatric congenital solitary kidney

Pediatr NephrolPublished Method comparison study

Authors' conclusion

The coronal plane volume measurement method, which has a significantly shorter examination and post-processing time, is a highly reproducible and reliable method that can enable volume measurement with MRI in younger children, as the imaging time will be shortened.

Study context

Population
Pediatric patients with congenital solitary kidneys
Comparison
Coronal axis FIESTA vs axial axis T2W MRI kidney volume measurement
Outcome
Intra-observer and inter-observer reliability of kidney volume measurement
Methodological detailsintra-observer and inter-observer reliability, free-hand manual tracing, two operators with different levels of experience
  • Intra-observer and inter-observer reliability
  • Free-hand manual tracing
  • Two operators with different levels of experience

Main finding

As reported in the abstract

Intra-observer and inter-observer reliability
GroupIntra-observer reliabilityInter-observer reliability
Axial0.9650.964
Coronal0.9720.963

Intra-observer reliability

Axial0.965
Coronal0.972

Inter-observer reliability

Axial0.964
Coronal0.963

Original publication

Comparison of axial and coronal axis MRI kidney volume measurement in pediatric congenital solitary kidney. Pediatr Nephrol. Published 22 December 2022. doi:10.1007/s00467-022-05858-x