Comparison of axial and coronal axis MRI kidney volume measurement in pediatric congenital solitary kidney
Authors' conclusion
The coronal plane volume measurement method, which has a significantly shorter examination and post-processing time, is a highly reproducible and reliable method that can enable volume measurement with MRI in younger children, as the imaging time will be shortened.
Study context
- Population
- Pediatric patients with congenital solitary kidneys
- Comparison
- Coronal axis FIESTA vs axial axis T2W MRI kidney volume measurement
- Outcome
- Intra-observer and inter-observer reliability of kidney volume measurement
Methodological detailsintra-observer and inter-observer reliability, free-hand manual tracing, two operators with different levels of experience
- Intra-observer and inter-observer reliability
- Free-hand manual tracing
- Two operators with different levels of experience
Main finding
As reported in the abstract
Intra-observer and inter-observer reliability
| Group | Intra-observer reliability | Inter-observer reliability |
|---|---|---|
| Axial | 0.965 | 0.964 |
| Coronal | 0.972 | 0.963 |
Intra-observer reliability
Axial0.965
Coronal0.972
Inter-observer reliability
Axial0.964
Coronal0.963
Key notes
- High intra-observer and inter-observer reliability for both measurement methods
- Reliability statistic not named in the abstract
Original publication
Comparison of axial and coronal axis MRI kidney volume measurement in pediatric congenital solitary kidney. Pediatr Nephrol. Published 22 December 2022. doi:10. 1007/ s00467-022-05858-x