Comparison of 99mTc-DTPA and 51Cr-EDTA for glomerular filtration rate measurement with the continuous infusion method

J NephrolPublished Prospective method-comparison study

Authors' conclusion

Urinary and plasma clearance of 99mTc-DTPA can be used with the infusion protocol to measure GFR.

Study context

Population
Patients referred for GFR measurement, February and March 2019
Participants
22 patients
Exposure
99mTc-DTPA vs 51Cr-EDTA for GFR measurement with the continuous infusion method
Outcome
Urinary and plasma clearance of 99mTc-DTPA vs 51Cr-EDTA
Follow-up
Over four and a half hours
Methodological detailssingle centre, both tracers given simultaneously through the same intravenous route, bolus plus continuous infusion
  • Single centre
  • Both tracers given simultaneously through the same intravenous route
  • Bolus plus continuous infusion

Main finding

As reported in the abstract

Urinary clearance

P = 0.47

Mean bias
0.39 ± 2.50 mL/min
Accuracy within 10%
100% (95% CI 100; 100)
Pearson correlation coefficient
0.994

Observational data: associations, not effects.

Further findings

Plasma clearance

P = 0.61

Plasma clearance

Mean bias
- 0.43 ± 3.89 mL/min
Accuracy within 10%
77% (95% CI 59; 91)
Pearson correlation coefficient
0.983

Original publication

Comparison of 99mTc-DTPA and 51Cr-EDTA for glomerular filtration rate measurement with the continuous infusion method. J Nephrol. Published 24 April 2023. doi:10.1007/s40620-023-01612-0

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.