Comparable rates of catheter-related bloodstream infections between non-tunneled and tunneled hemodialysis catheters: a retrospective single-center study
Authors' conclusion
Our study found no significant difference in the incidence of CRBSIs. We conclude that prolonged use of non-tunneled pre-curved catheters, which are easily managed, is a viable option for patients awaiting construction of arteriovenous fistula, insertion of a peritoneal catheter or kidney transplantation in a reasonable time. Promising results on long-term use from this study need to be confirmed in prospective studies.
Study context
- Population
- Patients dialyzed on an outpatient basis between 1 January 2018 and 1 July 2024, follow-up until 1 March 2025625 + 53 catheters
- Participants
- 301 patients
- Exposure
- Pre-curved non-tunneled vs tunneled HD catheters
- Outcome
- Rates of CRBSIs
Methodological detailssingle-centre
- Single-centre
Main finding
As reported in the abstract
Key notes
- Identical incidence rate in both groups
Observational data: associations, not effects.
Further findings
| Outcome | IRR (95% CI) | P value | |
|---|---|---|---|
| CRBSIs and possible CRBSIs (PCRBSIs) together | 1.14 (0.6–2.1) | P = 0.68 | |
| 0.512Incidence rate ratio (log scale) |
Catheter-related blood stream infections (CRBSIs) and possible CRBSIs (PCRBSIs) together
- Similar infection rates
CRBSI IRR, subanalysis in patients with both types of catheters during study period
- CRBSI IRR in 27 patients with both types of catheters
- 1.37 (0.55-3.41, P = .49)
CRBSI IRR, subanalysis after first CRBSI
- CRBSI IRR in 36 patients after their first CRBSI
- 2.01 (0.52-7.72, P = .47)
Time to CRBSI
- Time to CRBSI comparable in all analyses
Original publication
Composed by AI from the published abstract and checked against it. How Briefs are made →