Combined Creatinine and Cystatin C Equations Improve Estimation of Glomerular Filtration Rate in Kidney Transplant Recipients
Authors' conclusion
Combined creatinine/cystatin C eGFR equations with a P30 value greater to 85% of transplant recipients appeared closer to mGFR than cystatin C or creatinine eGFR.
Study context
- Population
- Kidney transplant recipients with measured GFR (mGFR) determination and simultaneous plasma enzymatic creatinine and serum cystatin C10 equations
- Participants
- 242 recipients
- Comparison
- Creatinine, cystatin C and combined creatinine/cystatin C estimated GFR (eGFR) equations vs mGFR (urinary clearance of 99mTc-DTPA)
- Outcome
- P30 (eGFR within 30% of mGFR)
Performance
As reported in the abstract
P30 (eGFR within 30% of mGFR)
Combined equations
85.5% to 87.6%
Cystatin C equations
83.1% to 84.3%
Creatinine equations
75.2% to 81.4%
Further findings
Correlation and bias vs mGFR, all equations
- R²
- 0.672-0.745
- Median bias (mL/min/1.73 m²)
- +4.2 to −1.1
- All equations significantly correlated with mGFR
CKD staging agreement
- All equations
- above 68%
- Maximum, CKD-EPI comb 2021
- 79.3%
Original publication
Combined Creatinine and Cystatin C Equations Improve Estimation of Glomerular Filtration Rate in Kidney Transplant Recipients. Transpl Int. Published 10 February 2026. doi:10. 3389/ ti. 2026. 15529