Kidney transplantation

Combined Creatinine and Cystatin C Equations Improve Estimation of Glomerular Filtration Rate in Kidney Transplant Recipients

Transpl IntPublished Diagnostic accuracy study

Authors' conclusion

Combined creatinine/cystatin C eGFR equations with a P30 value greater to 85% of transplant recipients appeared closer to mGFR than cystatin C or creatinine eGFR.

Study context

Population
Kidney transplant recipients with measured GFR (mGFR) determination and simultaneous plasma enzymatic creatinine and serum cystatin C10 equations
Participants
242 recipients
Comparison
Creatinine, cystatin C and combined creatinine/cystatin C estimated GFR (eGFR) equations vs mGFR (urinary clearance of 99mTc-DTPA)
Outcome
P30 (eGFR within 30% of mGFR)

Performance

As reported in the abstract

P30 (eGFR within 30% of mGFR)

Combined equations

85.5% to 87.6%

Cystatin C equations

83.1% to 84.3%

Creatinine equations

75.2% to 81.4%

Further findings

Correlation and bias vs mGFR, all equations

R²
0.672-0.745
Median bias (mL/min/1.73 m²)
+4.2 to −1.1
  • All equations significantly correlated with mGFR

CKD staging agreement

All equations
above 68%
Maximum, CKD-EPI comb 2021
79.3%

Original publication

Combined Creatinine and Cystatin C Equations Improve Estimation of Glomerular Filtration Rate in Kidney Transplant Recipients. Transpl Int. Published 10 February 2026. doi:10.3389/ti.2026.15529

Composed by AI from the published abstract and checked against it. How Briefs are made →