Hemodialysis

CD4 + CD25 + CD39 + Regulatory T Cells as Novel Diagnostic Biomarkers for Catheter‐Related Bloodstream Infections in Hemodialysis Patients

Hemodial IntPublished Prospective cohort study

Authors' conclusion

CD4+CD25+CD39+ Tregs represent a novel, high-performance biomarker for CRBSI. Combined with validated dialysis line cultures and fever thresholds, they enable rapid diagnosis and early intervention, offering a practical alternative to current culture-dependent approaches in hemodialysis patients.

Study context

Population
Hemodialysis (HD) patients with suspected catheter-related bloodstream infections (CRBSI)
Participants
87 patients
Exposure
CRBSI vs non-CRBSI controls
  • CRBSIn = 42
  • Non-CRBSIn = 45reference
Outcome
Diagnostic accuracy of CD4+CD25+CD39+ Tregs for CRBSI
Methodological detailsdiagnostic accuracy, flow cytometry, paired blood cultures from dialysis bloodlines and peripheral veins
  • Diagnostic accuracy
  • Flow cytometry
  • Paired blood cultures from dialysis bloodlines and peripheral veins

Main finding

As reported in the abstract

CD4+CD25+CD39+ Treg frequency

P < 0.001

Tregs, AUC
0.974
Tregs, sensitivity
98.3%
Tregs, specificity
96.3%

Observational data: associations, not effects.

Further findings

OutcomeORP value
Fever > 38.0°C predicting CRBSI18.67P < 0.001
Fever > 38.0°C predicting CRBSI — Specificity
85%

Dialysis bloodline vs peripheral cultures

Agreement
92%
κ
0.88

Diagnostic triad (Tregs > 10%, CRP > 50 mg/L, fever > 38.0°C)

AUC
0.93

Original publication