Catheter Event Rates in Medical Compared to Surgical Peritoneal Dialysis Catheter Insertion
Authors' conclusion
Offering both medical and surgical techniques is associated with lower catheter event rates and keeps people on PD for longer.
Study context
- Population
- Participants planned for first peritoneal dialysis (PD) catheter insertion in 44 UK centers784 first catheter insertions
- Exposure
- Medical vs surgical PD catheter insertion
- Outcome
- Catheter-related events:
- Catheter-related infection
- Hospitalization
- Removal
- Follow-up
- First year
Methodological detailsmulticentre, 44 UK centers, multistate model
- Multicentre
- 44 UK centers
- Multistate model
Main finding
As reported in the abstract
Catheter event
Medical vs SurgicalHazard ratio (95% CI)
Following insertion; adjusted for center factors
0.70(0.43–1.13)
Once established on PD; adjusted
0.77(0.62–0.96)
Observational data: associations, not effects.
Further findings
Any catheter event, all insertions · first year
- Insertions with a catheter event
- 466 (59%)
- Transitions onto hemodialysis (HD) immediately preceded by a catheter event
- 61.2%
Catheter malfunction and infection
- Malfunction less but infection more common with surgical vs medical insertion
Center factors
- Centers with fewer late presenters and more new dialysis patients starting PD had lower probability of a catheter event
Original publication
Catheter Event Rates in Medical Compared to Surgical Peritoneal Dialysis Catheter Insertion. Kidney Int Rep. Published 17 September 2023. doi:10. 1016/ j. ekir. 2023. 09. 015
Composed by AI from the published abstract and checked against it. How Briefs are made →