Cardiac Output Changes during Renal Replacement Therapy: A Scoping Review
Authors' conclusion
There are limited data on CO changes during RRT. However, a decrease in CO appeared common and was marked in 1 of 5 patient cohorts. Such decreases often occurred without BP changes and were associated with increased SVR.
Study context
- Population
- Studies of intermittent hemodialysis (IHD) and CRRT with at least three cardiac output (CO) measurements during treatment48 studies
- Outcome
- CO monitoring and changes during renal replacement therapy (RRT)
Methodological detailsdescriptive synthesis (no meta-analysis), two independent reviewers, MEDLINE, Embase and Cochrane searched January 1, 2000, to January 31, 2023; 3,285 articles screened
- Descriptive synthesis (no meta-analysis)
- Two independent reviewers
- MEDLINE, Embase and Cochrane searched January 1, 2000, to January 31, 2023; 3,285 articles screened
Pooled result
As reported in the abstract
CO changes during RRT
- Patient cohorts studied
- 88
- Cohorts with a decrease in CO
- 63 (72%)
- Cohorts with severe decrease (>25%)
- 16
- Median baseline cardiac index in IHD studies
- 3 L/min/m² (95% CI, 2.7-3.39)
- Correlation of CO decrease with ultrafiltration rate (weak)
- r = −0.3, p = 0.05
- Correlation of CO decrease with changes in systemic vascular resistance (SVR) (strong)
- r = −0.6, p < 0.001
Key notes
- Changes in blood pressure (BP) not concordant in extent or direction with changes in CO
- 37 studies during IHD, nine during CRRT, two during both
More notes
- Non-invasive devices most common CO technique (21 studies)
Original publication
Cardiac Output Changes during Renal Replacement Therapy: A Scoping Review. Blood Purif. Published 14 October 2023. doi:10. 1159/ 000534601
Composed by AI from the published abstract and checked against it. How Briefs are made →