Hemodialysis

Carbon Emissions From Different Dialysis Modalities: A Life Cycle Assessment

Am J Kidney DisPublished Comparative life cycle assessment

Authors' conclusion

In-center hemodialysis has a substantially higher carbon footprint than all home dialysis options, informing the choice of home dialysis when feasible and appropriate for individual patients.

Study context

Population
Dialysis treatments provided by the Royal Melbourne Hospital Kidney Care Service, Melbourne, Victoria, Australia
Comparison
In-center HD vs home HD vs automated peritoneal dialysis (APD) vs continuous ambulatory peritoneal dialysis (CAPD)
Outcome
Carbon emissions (kg CO2e) from the annual provision of dialysis to a single patient
Follow-up
Annual
Methodological detailsattributional process-based, single dialysis provider, urban setting
  • Attributional process-based
  • Single dialysis provider
  • Urban setting

Main finding

As reported in the abstract

Annual per patient carbon emissions

Annual per patient carbon emissions

Lower than in-center HD Home HD 41% · APD 29% · CAPD 59%

Further findings

Across all 4 modalities, consumables were the largest source of emissions
For in-center HD, patient travel was the main factor contributing to its higher carbon footprint vs home-based dialysis

Original publication

Carbon Emissions From Different Dialysis Modalities: A Life Cycle Assessment. Am J Kidney Dis. Published 30 June 2025. doi:10.1053/j.ajkd.2025.04.019

Composed by AI from the published abstract and checked against it. How Briefs are made →