Bias and Accuracy of Glomerular Filtration Rate Estimating Equations in the US: A Systematic Review and Meta-Analysis
Authors' conclusion
This systematic review and meta-analysis of GFR estimating equations suggests that there is bias in race-based GFR estimating equations, which exacerbates kidney disease disparities. Development of a GFR equation independent of race is a crucial starting point, but not the sole solution. Addressing the disproportionate burden of kidney failure on Black individuals in the US requires an enduring, multifaceted approach that should include improving diagnostics, tackling social determinants of health, confronting systemic racism, and using effective disease prevention and management strategies.
Study context
- Population
- Adults in studies comparing mGFR with eGFR using established reference standards and methods, including individuals with chronic conditions
- Participants
- 44,721 adults12 studies
- Comparison
- Performance of glomerular filtration rate (GFR) estimating equations in Black vs non-Black persons
- Outcome
- Bias (median difference between mGFR and eGFR) and accuracy (P30) of eGFR in Black vs non-Black patients and in individuals with chronic conditions
Methodological detailsrandom-effects model, PRISMA guidelines, 2 authors independently extracted data, Databases searched January 2012 to February 2023; 6663 studies initially identified
- Random-effects model
- PRISMA guidelines
- 2 authors independently extracted data
- Databases searched January 2012 to February 2023; 6663 studies initially identified
Pooled result
As reported in the abstract
Overall P30
mL/min/1.73 m²
| Outcome | Black | Non-Black |
|---|---|---|
| Mean bias, creatinine-based equations | 2.1 (95% CI, −0.2 to 4.4) | 1.3 (95% CI, 0.0 to 2.5) |
Key notes
- Significant heterogeneity in the bias of various GFR estimation equations
- Race-corrected and creatinine-based equations tended to overestimate GFR in Black populations; mixed results in non-Black populations
More notes
- Cystatin C-only equations had small biases
- Accuracy heterogeneity high in both groups
- Creatinine-based equations more accurate in non-Black than in Black persons
- Creatinine-cystatin C equations: P30 higher in non-Black persons
- Cystatin C-only equations: no significant P30 difference between the 2 groups
- The group values are overall P30
Further findings
Patients with chronic conditions
- P30 generally less than 85%; biases varied widely
Original publication
Composed by AI from the published abstract and checked against it. How Briefs are made →