Chronic kidney disease

Average creatinine–urea clearance: revival of an old analytical technique?

Clin Kidney JPublished Diagnostic accuracy study

Authors' conclusion

The study described the best performance of mClUN-cr at GFR levels below 60 mL/min/1.73 m2 and a satisfactory result in the overall cohort. The findings point to a role of this tool, especially for estimating GFR in chronic kidney disease patients in developing countries, when reference measurement of GFR is not available.

Study context

Population
Participants who performed a GFR measurement by urinary inulin clearance
Participants
855 participants
Comparison
mClUN-cr vs CKD-EPI 2009 and CKD-EPI 2021, against urinary inulin clearance
Outcome
Performance (bias, precision and accuracy) vs mGFR by urinary inulin clearance
Methodological detailscross-sectional
  • Cross-sectional

Performance

As reported in the abstract

Performance vs mGFR, whole sample
Test or modelPrecisionAccuracy P30
mClUN-cr11.5 (95% CI 10.5; 12.5)97.0 (95% CI 95.8; 98.0)
CKD-EPI 200919.0 (95% CI 17.2; 20.1)82.0 (95% CI 79.2; 84.4)
CKD-EPI 202119.1 (95% CI 17.4; 20.4)77.2 (95% CI 74.5; 80.0)

Precision

mClUN-cr11.5 (95% CI 10.5; 12.5)
CKD-EPI 200919.0 (95% CI 17.2; 20.1)
CKD-EPI 202119.1 (95% CI 17.4; 20.4)

Accuracy P30

mClUN-cr97.0 (95% CI 95.8; 98.0)
CKD-EPI 200982.0 (95% CI 79.2; 84.4)
CKD-EPI 202177.2 (95% CI 74.5; 80.0)

Further findings

Performance by mGFR level

CKD-EPI equations (2009 and 2021) had the best performance when mGFR >60 mL/min/1.73 m²
mClUN-cr performed better than others at lowest mGFR values, more noticeable when mGFR <60 mL/min/1.73 m²

Original publication

Average creatinine–urea clearance: revival of an old analytical technique? Clin Kidney J. Published 26 May 2023. doi:10.1093/ckj/sfad050

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.