Assessing Fatigue in Patients Receiving Kidney Replacement Therapy Using Patient Reported Outcome Measurement Information System (PROMIS) Computer Adaptive Testing

Am J Kidney DisPublished Cross-sectional study

Authors' conclusion

PROMIS-F CAT has robust measurement properties with low question burden to assess fatigue among patients with KRT.

Study context

Population
Adults treated with dialysis or kidney transplant recipients in Toronto, Canada65% kidney transplant
Participants
198 adults
Exposure
PROMIS-F CAT vs Functional Assessment of Chronic Illness Therapy-Fatigue (FACIT-F) questionnaire
Outcome
Measurement properties of PROMIS-F CAT T scores

Main finding

As reported in the abstract

Measurement properties of PROMIS-F CAT
GroupCorrelation with FACIT-F (ρ)ReliabilityTest-retest reliability (intraclass correlation coefficient (ICC))AUCSensitivity (cutoff ≥59)Specificity (cutoff ≥59)
PROMIS-F CAT−0.80>0.90 for 98% of sample0.850.93 (95% CI 0.89-0.97)0.830.91

PROMIS-F CAT

Correlation with FACIT-F (ρ)−0.80
Reliability>0.90 for 98% of sample
Test-retest reliability (intraclass correlation coefficient (ICC))0.85
AUC0.93 (95% CI 0.89-0.97)
Sensitivity (cutoff ≥59)0.83
Specificity (cutoff ≥59)0.91
PROMIS-F CAT and FACIT-F strongly correlated, P<0.001
ρ =−0.80

Observational data: associations, not effects.

Further findings

Clinically relevant fatigue (FACIT-F)

Patients with clinically relevant fatigue
47 (24%)

Original publication

Assessing Fatigue in Patients Receiving Kidney Replacement Therapy Using PROMIS Computer Adaptive Testing. Am J Kidney Dis. Published 9 March 2023. doi:10.1053/j.ajkd.2022.12.018

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.