Are Mid-Dialysis Handgrip Strength Measurements Reliable and Reproducible? A Comparison to Predialysis Handgrip Strength Measurements
Main finding · HGSResult — go to the resultMean difference 0.5 kgAuthors' conclusion
This study found that HGS taken either pre- or mid-dialysis was reliable and reproducible. Given the agreement between pre- and mid-dialysis HGS measures, HGS measured mid-dialysis may be used for nutritional assessment of HD patients.
Study context
- Population
- Patients stable on hemodialysis (HD) for at least 3 months and not acutely unwell, from 4 Australian HD units4 HD units
- Participants
- 48 participants
- Comparison
- Predialysis vs mid-dialysis handgrip strength (HGS) measurement
- Outcome
- Reliability, reproducibility and agreement of HGS values pre- and mid-dialysis
Methodological detailsmulticentre, repeated measures over 3 consecutive weeks, Bland-Altman agreement analysis, linear mixed models
- Multicentre
- Repeated measures over 3 consecutive weeks
- Bland-Altman agreement analysis
- Linear mixed models
Main finding
HGS
As reported in the abstract
Key notes
- Bland-Altman plots: acceptable agreement between pre- and mid-dialysis HGS, suggesting no systematic bias
- Higher with Predialysis; statistically but not clinically greater
Further findings
- Influence of confounders (gender, age, dialysis vintage, frailty, nutritional status, ultrafiltration rate, fluid overload, diabetes, peripheral vascular disease, weight) on pre- vs mid-dialysis differences not statistically significant
Original publication
Are Mid-Dialysis Handgrip Strength Measurements Reliable and Reproducible? A Comparison to Predialysis Handgrip Strength Measurements. J Ren Nutr. Published 30 September 2025. doi:10. 1053/ j. jrn. 2025. 09. 004