Kidney transplantation

Antibody-mediated rejection in ABO-incompatible kidney transplantation

Nephrol Dial TransplantPublished Retrospective cohort study

Authors' conclusion

ABOi transplantation reduces the risk of developing de novo anti-HLA DSA. Banff 2022 criteria may over-diagnose AMR. Biopsy-based transcript diagnostics differentiate anti-HLA- and anti-A/B-mediated alloimmune injury from C4d deposition due to accommodation. Interestingly, C4d deposition drives molecular AMR activity in ABOc biopsies.

Study context

Population
Kidney transplant recipients, ABO-incompatible (ABOi) and ABO-compatible (ABOc)25 ABOi biopsies by MMDx
Participants
66 vs 251
Exposure
ABOi vs ABOc kidney transplantation
  • ABOin = 66
  • ABOcn = 251reference
Outcome
Anti-HLA DSA development
Methodological detailsprotocol biopsies, Banff 2022 classification, Molecular Microscope Diagnostics System (MMDx)
  • Protocol biopsies
  • Banff 2022 classification
  • Molecular Microscope Diagnostics System (MMDx)

Main finding

As reported in the abstract

De novo anti-HLA DSA
  • ABOi vs ABOc: P = 0.001

Observational data: associations, not effects.

Further findings

OutcomeP value
Clinical AMRLower rates with ABOiP = 0.018

Antibody-mediated rejection (AMR) in 25 ABOi protocol biopsies (MMDx)

Met Banff AMR criteria due to anti-A/B donor-specific antibodies (DSA)
56%
Active AMR
20%
Probable AMR
20%
Chronic AMR
16%
Molecular AMR confirmed by MMDx
14%
P
P < 0.001

ABOi vs DSA-negative, C4d-negative ABOc biopsies with microvascular inflammation (MVI) below threshold

Did not differ in molecular rejection, archetype and lesion scores; stable graft function
P > 0.05

Molecular AMR classifier scores

Significantly lower in ABOi and DSA-negative, C4d-negative ABOc cases with MVI below threshold vs C4d-positive ABOc and ABOc with probable AMR
P = 0.007

C4d and molecular AMR activity in ABOc biopsies

C4d drives molecular AMR activity already at C4d1 levels by immunofluorescence
P = 0.011
Even in absence of histological Banff AMR diagnosis
P = 0.003

Original publication