Chronic kidney disease

Accuracy of Point-of-Care Transdermal Glomerular Filtration Rate (GFR) Methodology

Kidney Int RepPublished Diagnostic accuracy study

Authors' conclusion

The tGFR yielded a higher P30 value than creatinine-based eGFR equations reported in the current literature. For the cohort subsets of CKD strata and FSS, all P30 values observed were in the optimal range as established by the 2024 Kidney Disease: Improving Global Outcomes guideline.

Study context

Population
Participants with normal estimated GFR (eGFR) to chronic kidney disease (CKD) stage 4 across all 6 Fitzpatrick Skin Scale types
Participants
182 participants
Comparison
Transdermal GFR vs plasma-derived indexed GFR
Outcome
Percentage of tGFR values within 30% of nGFR (P30)
Methodological detailsmulticenter, pivotal clinical study
  • Multicenter
  • Pivotal clinical study

Performance

As reported in the abstract

P30 (% of tGFR values within 30% of nGFR)

P30, entire cohort

94%

95% CI 89%–97%

Further findings

P30 by GFR

GFR >60 ml/min per 1.73 m²
96%
GFR <60 ml/min per 1.73 m²
92%

P30 by Fitzpatrick Skin Scale

Fitzpatrick Skin Scale (FSS) I to III
96%
FSS IV to VI
90%

Original publication

Accuracy of Point-of-Care Transdermal GFR Methodology. Kidney Int Rep. Published 22 January 2026. doi:10.1016/j.ekir.2026.103797