Kidney transplantation

A Pre-Kidney Transplant Blood-Based Next-Generation Sequencing Assay to Predict Early Acute Rejection

Kidney360Published Diagnostic accuracy study

Performance · EAR prediction by PTRAResult — go to the resultOdds ratio 7.04 95% CI 1.64–30.2

Authors' conclusion

This study validates the ability of PTRA to stratify kidney transplant recipients as high or low risk for EAR using a pretransplant transcriptomic profile, with implications for graft health and personalized treatment management.

Study context

Population
Deceased donor kidney transplant recipients (clinical validation of a pretransplant 29-gene RNA expression signature)122 in validation
Participants
321 recipients
Comparison
Pretransplant risk assessment (PTRA) high risk vs low risk
  • High riskn = 31
  • Low riskn = 91reference
Outcome
Early acute rejection (EAR)
Follow-up
60 days post-transplant
Methodological detailsprospective, international, 13 sites, discovery and validation cohorts, blinded central pathologist, 2019 Banff criteria
  • Prospective
  • International
  • 13 sites
  • Discovery and validation cohorts
  • Blinded central pathologist
  • 2019 Banff criteria

Performance

EAR prediction by PTRA

Odds ratio

7.04

95% CI 1.64–30.2

P = 0.009

Events by group

High riskvs Low risk
OR 7.04 (95% CI 1.64–30.2); P = 0.009

As reported in the abstract

AUC
0.78 (95% CI, 64.4 to 91.5), P < 0.001
Sensitivity
0.67 (95% CI, 0.36 to 0.97)
Specificity
0.78 (95% CI, 0.70 to 0.86)
PPV
0.19 (95% CI, 0.05 to 0.33)
NPV
0.97 (95% CI, 0.93 to 1.00)

Original publication

A Pre-Kidney Transplant Blood-Based Next-Generation Sequencing Assay to Predict Early Acute Rejection. Kidney360. Published 14 May 2026. doi:10.34067/kid.0000001208

Composed by AI from the published abstract and checked against it. How Briefs are made →

Get them every week

New studies on this topic in My Week and in your Monday e-mail.

We e-mail you a sign-in link and a code. No password, no spam.