A Comprehensive Assessment of Plasma CXCL9 and CXCL10 in Improving Clinical Prediction Models for Kidney Allograft Rejection
Performance · Prediction of need for antirejection therapyResult — go to the resultDelta ROC-AUC 0.02Authors' conclusion
These findings suggest that adding plasma CXCL9 or CXCL10 to a benchmark model can improve patient care by reducing the number of biopsies in individuals unlikely to require antirejection therapy.
Study context
- Population
- Consecutively transplanted kidney recipients on standard immunosuppression43 (26.4%) needed antirejection therapy
- Participants
- 163 participants
- Comparison
- Benchmark model extended with plasma CXCL9 or CXCL10 vs benchmark model
- Outcome
- Prediction of the need for antirejection treatment
- Follow-up
- Between Days 3 and 21 posttransplant
Methodological detailsconsecutive recipients, internal validation by bootstrapping, likelihood ratio tests, ROC-AUC, flexible calibration curves, net benefit analysis
- Consecutive recipients
- Internal validation by bootstrapping
- Likelihood ratio tests
- ROC-AUC
- Flexible calibration curves
- Net benefit analysis
Performance
Prediction of need for antirejection therapy · Days 3–21 posttransplant
- Better clinical utility across biopsy risk thresholds; up to fewer unnecessary biopsies per 100 patients
- 17
Key notes
- Chemokine-extended models vs Benchmark: P < 0.01
- Improved calibration
More notes
- Increased discriminative ability
Original publication
A Comprehensive Assessment of Plasma CXCL9 and CXCL10 in Improving Clinical Prediction Models for Kidney Allograft Rejection. Clin Transplant. Published 2 September 2025. doi:10. 1111/ ctr. 70299