A Cell-Based Assay to Measure the Activity of the Complement Convertases
Authors' conclusion
We provided a proof-of-concept of a new assay that detects convertase overactivity in individuals carrying variants of both pathogenic character or those of unknown significance in ubiquitous complement proteins such as C3.
Study context
- Population
- Nephrological patients harboring C3 genetic variants and asymptomatic relatives carrying the same pathogenic C3 variant
- Outcome
- Convertase activity assay performance
Methodological detailsproof-of-concept, cell-based assay, Antibody-sensitized human lymphoma cell line activates the classical pathway (CP) with alternative pathway (AP) amplification; C5 blockers eculizumab and crovalimab halt the cascade at the convertases; after washout, guinea pig serum in ethylenediamine tetraacetic acid (EDTA) buffer develops lytic sites on preexisting convertases
- Proof-of-concept
- Cell-based assay
- Antibody-sensitized human lymphoma cell line activates the CP with AP amplification; C5 blockers eculizumab and crovalimab halt the cascade at the convertases; after washout, guinea pig serum in EDTA buffer develops lytic sites on preexisting convertases
Main finding
As reported in the abstract
- Assay detects recombinant gain-of-function components of both convertase types (CP/lectin pathway (LP) and AP) within human serum or plasma
- Practical utility in analyzing nephrological patients harboring C3 genetic variants
- Distinguishes between patients and asymptomatic relatives carrying the same pathogenic C3 variant
Original publication
A Cell-Based Assay to Measure the Activity of the Complement Convertases. Kidney Int Rep. Published 4 May 2024. doi:10. 1016/ j. ekir. 2024. 04. 058